OPERATION
B-6 B-6
V350-PRO
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Auxiliary Power
• 115VAC, 42VAC and 24VAC power is available
from the two 14-pin amphenols on the rear of the
unit. (K1728-2 Construction model of the Invertec
V350-Pro does not have the amphenols) These
supplies are intended to supply power for auxiliary
equipment like wire feeders and the TIG Module.
• 115VAC supply is rated at 2 amps and is protected
by a 2.5 amp breaker located by the amphenol.
• 42 VAC supply is rated at 5.5 amps and is protect-
ed by a 6 amp breaker located by the amphenol.
• 24 VAC supply is rated at 5.5 amps and is protect-
ed by a 6 amp breaker located by the amphenol.
Limitations
The V350-Pro is not recommended for processes
other than those listed.
The V350-Pro can only be used with the recom-
mended equipment and options.
Recommended Processes
Properly equipped, the Invertec V350-Pro supports
GMAW, FCAW, SMAW, GTAW and CAC-A
processes for a variety of materials, including mild
steel, stainless steel, cored wires, and aluminum.