TROUBLESHOOTING AND REPAIR
RETEST AFTER REPAIR
F-94 F-94
V350-PRO
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Retest a machine:
If it is rejected under test for any reason that requires you to remove any part which could affect the
machine’s electrical characteristics.
If you repair or replace any electrical components:
IDLE AMPS
Input Volts
230VAC
460VAC
575VAC
Maximum Idle Amps
Less Than 1.0 Amp
Less Than 0.5 Amp
Less Than 0.5 Amp
Idle Watts
400 Watts
400 Watts
400 Watts
Note: The machine’s output terminals should be energized but with no external load on the
machine.
PERFORM THE VOLTAGE AND CURRENT CALIBRATION PROCEDURE
This procedure is necessary to insure that the machine is capable of producing output and that the unit is
calibrated correctly.
FAN AS NEEDED (F.A.N.)
The fan should turn on when the machine’s output terminals are energized and stay on for approximately
5 minutes after the output terminals are de-energized.