Page view 118
TROUBLESHOOTING & REPAIR
F-81 F-81
V350-PRO
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
INPUT RECTIFIER REMOVAL AND REPLACEMENT
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical
troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
DESCRIPTION
The following procedure will aid the technician in removing the input rectifier for maintenance
or replacement.
MATERIALS NEEDED
3/16” Allen wrench
5/16” Nut Driver
Flathead Screwdriver
Penetrox A-13 Heatsink Compound
Silicon Sealant
WARNING
This procedure takes approximately 20 minutes to perform.