A-8
INSTALLATION
VANTAGE® 575 CUMMINS
A-8
CONNECTION OF AN NA-3 AUTOMATIC
WELDING SYSTEM TO THE VANTAGE®
575 CUMMINS
For connection diagrams and instructions for connect-
ing an NA-3 Welding System to the VANTAGE® 575
CUMMINS, refer to the NA-3 Welding System instruc-
tion manual. The connection diagram for the LN-8 can
be used for connecting the NA-3.
• Set the Wire Feeder Voltage Switch to 115V.
CONNECTION OF MAGNUM SC SPOOL
GUN TO THE VANTAGE® 575 CUMMINS
(SEE SECTION F)
Spool Gun (K487-25) and Cobramatic to VAN-
TAGE® 575 CUMMINS.
• Shut the welder off.
Connect per instructions on the appropriate connec-
tion diagram in Section F.
CONNECTION OF THE LN-25 TO THE
VAN-
TAGE® 575 CUMMINS
.
Shut off welder before making any electrical con-
nections.
--------------------------------------------------------------------------
The LN-25 with or without an internal contactor may be
used with the
VANTAGE® 575 CUMMINS
. See the
appropriate connection diagram in Section F.
NOTE: The LN-25 (K431) Remote Control Module and
(K432) Remote Cable are not recommended for use
with the
VANTAGE® 575 CUMMINS
.
1. Shut the welder off.
2. For electrode Positive, connect the electrode cable
from the LN-25 to the "+" terminal of the welder and
work cable to the "-" terminal of the welder. For
electrode Negative, connect the electrode cable
from the LN-25 to the "-" terminal of the welder and
work cable to the "+" terminal of the welder.
3. Attach the single lead from the front of the LN-25 to
work using the spring clip at the end of the lead.
This is a control lead to supply current to the wire
feeder motor; it does not carry welding current.
4. Set the MODE switch to the "CV-WIRE " position.
5. Set the "WELD TERMINALS" switch to "WELD
TERMINALS ON"
6. Set the "ARC CONTROL" knob to "0" initially and
adjust to suit.
7. Set the "IDLE" switch to the "AUTO" position. When
not welding, the
VANTAGE® 575 CUMMINS
engine will be at the low idle speed. If you are using
an LN-25 with an internal contactor, the electrode is
not energized until the gun trigger is closed.
8. When the gun trigger is closed, the current sensing
circuit will cause the
VANTAGE® 575 CUMMINS
engine to go to the high idle speed, the wire will
begin to feed and the welding process started.
When welding is stopped, the engine will revert to
low idle speed after approximately 12 seconds
unless welding is resumed.
If you are using an LN-25 without an internal con-
tactor, the electrode will be energized when the
VANTAGE® 575 CUMMINS
is started.
--------------------------------------------------------------------------
WARNING
CAUTION