Lincoln-electric Mobiflex 400-MS User Manual

Browse online or download User Manual for Tools Lincoln-electric Mobiflex 400-MS. Lincoln Electric Mobiflex 400-MS User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 29
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Mobiflex 400-MS
OPERATOR’S MANUAL
IM667
April, 1999
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
When assembling a new package
start with this manual.
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
World's Leader in Welding and Cutting Products Premier Manufacturer of Industrial Motors
RETURN TO MAIN MENU
Page view 0
1 2 3 4 5 6 ... 28 29

Summary of Contents

Page 1 - Mobiflex 400-MS

Mobiflex 400-MSOPERATOR’S MANUALIM667April, 1999Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety in mind

Page 2 - MAGNETIC FIELDS

A-3INSTALLATION MOBIFLEX 400-MSA-3Only qualified personnel should install, use or servicethis equipment.--------------------------------------------

Page 3 - FUMES AND GASES

A-4INSTALLATION MOBIFLEX 400-MSA-4MOUNTING THE EXTRACTION ARM(continued)Place the other rubber seal around base of the armtube. MOUNT THE ARM IN THE

Page 4

A-5INSTALLATION MOBIFLEX 400-MSA-5INSTALLING THE LAMP AND ARCSENSOR OPTIONS The optional K1706-1 Work Lamp package providesa lamp and convenient hoo

Page 5 - REDRESSEUR

A-6INSTALLATION MOBIFLEX 400-MSA-6INSTALLING THE OPTIONALLAMP KIT AND AUTOMATICSTART/STOP ARC SENSOR(continued)Route the 13 ft. connecting cable th

Page 6 - Thank You

A-7INSTALLATION MOBIFLEX 400-MSA-7INSTALLING THE LAMP AND ARCSENSOR OPTIONS (continued)Loosen the four screws of the cover, lift the coveraround the

Page 7 - TABLE OF CONTENTS

B-1OPERATIONB-1Read and understand this entire section before oper-ating your Mobiflex 400-MS.SAFETY INSTRUCTIONSDo not attempt to use this equipment

Page 8

B-2OPERATIONB-2MOBIFLEX 400-MSTHE 400-MS FILTER CLEANING SYSTEM(Continued)The filter indicator will light during each automaticcleaning pulse, or duri

Page 9

MOBIFLEX 400-MSC-1MAINTENANCEC-1ROUTINE MAINTENANCEEvery 3 months, clean the inside of the machine witha vacuum cleaner, including the filter compart

Page 10 - INSTALLATION

D-1TROUBLESHOOTINGD-1MOBIFLEX 400-MSObserve all Safety Guidelines detailed througout this manualIf for any reason you do not understand the test proce

Page 11

D-1TROUBLESHOOTINGD-2MOBIFLEX 400-MSObserve all Safety Guidelines detailed througout this manualIf for any reason you do not understand the test proce

Page 12

FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

Page 13

E-1MOBIFLEX 400-MSWIRING DIAGRAM FOR K1741-1 MOBIFLEX 4OO-MSE-1DIAGRAMS    

Page 14

DIAGRAMSMOBIFLEX 400-MSE-2E-2WIRING DIAGRAM FOR MOBIFLEX 4OO-M S WITH LAMP AND ARC SENSOR OPTION       

Page 15 - OPERATION

MOBIFLEX 400-MSP-359P-359PARTS LIST FORMobiflex 400-MSThis parts list is provided as an informative guide only.This information was accurate at the ti

Page 16

4-23-99MOBIFLEX 400-MSDo Not use this Parts List for a machine if its code number is not listed. Contact the Service Department for anycode numbers no

Page 17 - MAINTENANCE

4-30-99MOBIFLEX 400-MSP-359-CP-359-CMOBIFLEX 400-MS ASSEMBLY

Page 18 - TROUBLESHOOTING

Recommended Spare Parts are Highlighted in Bold1 Fan Housing, Motor Side S23281-1 1 X2 Fan Wheel S23281-2 1 X3 Control Housing, Mobiflex S23281-3 1 X4

Page 19

MOBIFLEX 400-MSNOTES

Page 20 - DIAGRAMS

Now Available...12th EditionThe Procedure Handbook of Arc WeldingWith over 500,000 copies of previous editions publishedsince 1933, the Procedure Hand

Page 21

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Page 22

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Page 23

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld

Page 24 - MOBIFLEX 400-MS ASSEMBLY

FOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b. Install equ

Page 25

ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instruc-tions et les précautions de sûreté specifiques qui par

Page 26 - MOBIFLEX 400-MS

Thank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••• as much p

Page 27 - Lincoln Welding School

viTABLE OF CONTENTSPageSafety ...

Page 28

16.4 ft (5 m)AB13.12 ft (4 m)9.84 ft (3 m)6.56 ft (2 m)3.28 ft (1 m)0 ft (0 m)13.12 ft(4 m)9.84 ft(3 m)6.56 ft(2 m)3.28 ft(1 m)0 ft(0 m)MOBIFLEX 400-

Page 29

When the pressure drop across the filter reaches a setpoint due to increased fume on the outside of the fil-ter, a solenoid releases air from a compre