RED-D-ARC
DC-600
IM657
December, 2000
Red-D-Arc Spec-Built Welding Equipment
This RED-D-ARC welder is built to RED-D-ARC Extreme Duty
design specifications by Lincoln Electric.
Safety Depends on You
This welder is designed and built with safety in mind.
However, your overall safety can be increased by proper installation
... and thoughtful operation on your part.
DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT
WITHOUT READING THIS MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED THROUGHOUT.
And, most importantly, think before you act and be careful.
For use with machines having Code Numbers:
10650
North America’s Largest Fleet of Welding Equipment
1-800-245-3660
OPERATOR’S MANUAL
RETURN TO MAIN MENU
Page view 0
1 2 3 4 5 6 ... 51 52

Summary of Contents

Page 1 - RED-D-ARC

RED-D-ARCDC-600IM657December, 2000Red-D-Arc Spec-Built Welding EquipmentThis RED-D-ARC welder is built to RED-D-ARC Extreme Dutydesign specifications

Page 2 - MAGNETIC FIELDS

DC-600A-2INSTALLATION A-2Read entire Installation Section before installingthe DC-600.SAFETY PRECAUTIONSELECTRIC SHOCK CAN KILL.• Only qualified per

Page 3 - FUMES AND GASES

DC-600A-3INSTALLATION A-3ELECTRICAL INPUT CONNECTIONSBefore installing the machine check that the input sup-ply voltage, phase, and frequency are th

Page 4

DC-600A-4INSTALLATION A-4RECONNECT PROCEDUREMultiple voltage machines are shipped connected tothe highest input voltage listed on the machine’s rati

Page 5 - REDRESSEUR

DC-600A-5INSTALLATION A-5OUTPUT CONNECTIONSSee Table A.1 for recommended DC-600 cable sizes for combined lengths of electrode and work cables.TABLE

Page 6 - Thank You

TERMINAL STRIPSTerminal strips are available behind the cover on thecase front to connect wire feeder control cables thatdo not have a 14 Pin MS-type

Page 7 - TABLE OF CONTENTS

B-1OPERATIONB-1ELECTRIC SHOCKcan kill.• Do not touch electrically live partsor electrode with skin or wetclothing.• Insulate yourself from work andgro

Page 8

B-2OPERATIONB-2GENERAL DESCRIPTIONThe DC-600 is an SCR controlled three phase weldingand cutting power source. It uses a single rangepotentiometer to

Page 9

B-3OPERATIONB-3WELDING CAPABILITYThe DC-600 has the following Output and Duty Cycle based on operation for a 10 minute period:600 Amps, 44 Volts at 10

Page 10 - __________________

B-4OPERATIONB-43 Phase transformer with rectifiedDC outputLine ConnectionThree Phase Input PowerDesignates welder complies withNational Electrical Man

Page 11 - INSTALLATION

B-5OPERATIONB-5CONTROLS AND SETTINGSAll operator controls and adjustments are located on the Case Front Assembly of the DC-600. See Figure B.1 forthe

Page 12

DC-600FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be ru

Page 13

B-6OPERATIONB-66. Mode SwitchThis switch allows for selecting the weldingprocess to be used:CC STICK-for SMAW and AACCV SUBMERGED ARC- for SAWCV INNER

Page 14

B-7OPERATIONB-7OPERATING STEPSThe following procedures are for using the DC-600 inthe local control mode of operation. For remote con-trol of the mac

Page 15 - OPERATION

B-8OPERATIONB-8SEMI-AUTOMATIC AND AUTOMATICWIRE FEEDING WITH THE DC-600AND WIRE FEEDERSWhen using the DC-600 with semi-automatic or auto-matic wire fe

Page 16

B-9OPERATIONB-9ARC STRIKING WITH DC-600 AND THE NA-3START BOARDWhen electrical strikeouts exceed 1 3/4” (44.4mm) anNA-3 Start Board may be required to

Page 17

B-10OPERATIONB-10DC-600 POWER SOURCE SETTING WHENCONNECTED TO NA-5 WIRE FEEDERWhen using the DC-600 with the NA-5 wire feeder, setthe controls on the

Page 18

Undercarriages (K817P, K842)For easy moving of the machine, optional undercar-riages are available with polyolefin wheels (K817P) ora platform underca

Page 19

DC-600C-2ACCESSORIESC-2The MULTI-PROCESS SWITCH has two sets of out-put terminals. You connect the wire feeder unit cablesto the set of terminals on

Page 20

C-3ACCESSORIESC-312. Connect stick or air/carbon arc electrode and workcable. See Figure C.2.a. Insert the electrode and work cables throughthe strai

Page 21

ROUTINE AND PERIODIC MAINTENANCE1. Disconnect input AC power supply lines to themachine before performing periodic maintenance,tightening, cleaning, o

Page 22

E-1TROUBLESHOOTINGE-1If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal

Page 23

DC-600iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc whe

Page 24

E-2TROUBLESHOOTINGE-2CAUTION: Sometimes machine failures appear to bedue to PC board failures. These problems can some-times be traced to poor electri

Page 25 - ACCESSORIES

*(%+")%%*$If all recommended possible areasof misadjustment have beenchecked and the problem persists,?>D13DI?EB<?31<ED

Page 26

E-4TROUBLESHOOTINGE-4If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal

Page 27

E-5TROUBLESHOOTINGE-5If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal

Page 28 - MAINTENANCE

E-6TROUBLESHOOTINGE-6If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal

Page 29 - TROUBLESHOOTING

E-7TROUBLESHOOTINGE-7If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal

Page 30

E-8TROUBLESHOOTINGE-8If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal

Page 31 - *(%+")%%*$

E-9TROUBLESHOOTINGE-9If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal

Page 32

E-10TROUBLESHOOTINGE-10If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLoca

Page 33

E-11TROUBLESHOOTINGE-11If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLoca

Page 34

DC-600FOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b. Insta

Page 35

F-1DIAGRAMSF-1DC-600 NOTES:N.D. WELDING CABLE MUST BE OF THE PROPERCAPACITY FOR THE CURRENT AND DUTY CYCLEOF IMMEDIATE AND FUTURE APPLICATIONS."

Page 36

DC-600F-2DIAGRAMSF-2 S20409 1-28-94 CONNECTION OF LN-742 TO THE CV-655, DC-655 OR DC

Page 37

F-3DIAGRAMSF-3DC-600 N.C. Tape up bolted connection if lead #21 is extended. N.D. Connect the control cable ground lead to the frame terminal

Page 38

F-4DIAGRAMSF-4DC-600 N.C. Tape up bolted connection if lead #21 is extended. N.D. Connect the control cable ground lead to the frame terminal

Page 39

F-5DIAGRAMSF-5DC-600 Above diagram shows electrode connected positive. To change polarity, turn power off, reverse the electrode and work leads at th

Page 40 - DIAGRAMS

F-6DIAGRAMSF-6DC-600NEGATIVEPOSITIVE323124GND21N.A.N.D.TO WORKPOWER SOURCEOnly qualified persons should install, use orservice this machine.Do not ope

Page 41

F-7DIAGRAMSF-7DC-600 S22980 ELECTRODE CABLE-+14 PINAMPHENOLPOWER SOURCETO WORK AND 14-PIN CABL

Page 42

F-8DIAGRAMSF-8DC-600LOCATION OF BASE MOUNTING HOLES.94****20.00M12244-6DC-6001-20-89A27.879.2027.503.2539.9522.2529.93THIS DIMENSION WILL VARYWITH POS

Page 43

F-9DIAGRAMSF-96-18-93C36.12M15200-317.7638.005.19DIMENSION PRINT (WITH K842 UNDERCARRIAGE)20.0027.65*37.86LOCATION OF BASE MOUNTING HOLES**29.93.94**3

Page 44

Now Available...12th EditionThe Procedure Handbook of Arc WeldingWith over 500,000 copies of previous editions publishedsince 1933, the Procedure Hand

Page 45 - for more information

DC-600ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui

Page 46

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Page 47

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Page 48

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB

Page 49 - Lincoln Welding School

DC-600Thank Youfor selecting this QUALITY product. We want you to take pride inoperating this product ••• as much pride as we have in bringingthis pro

Page 50

viTABLE OF CONTENTSPageInstallation ...Section ATe

Page 51

viiTABLE OF CONTENTSPageMaintenance .......Section DSafet

Page 52

DC-60060% Duty Cycle122/61/49A-1INSTALLATION A-1TECHNICAL SPECIFICATIONS – DC-600Volts at Rated Amperes444444AuxiliaryPowerSee the OPERATION section