Operator’s ManualBIG RED ™ 600Register your machine: www.lincolnelectric.com/registerAuthorized Service and Distributor Locator: www.lincolnelectric
A-2INSTALLATION BIG RED™ 600A-2SAFETY PRECAUTIONRead this entire installation section before you startinstallation.LOCATION AND VENTILATIONThe welde
A-3INSTALLATION BIG RED™ 600A-3TOWINGUse a recommended trailer for use with this equip-ment for road, in-plant and yard towing by a vehi-cle(1). If
A-4INSTALLATION BIG RED™ 600A-4ENGINE BREAK-INLincoln Electric selects high quality, heavy-duty indus-trial engines for the portable welding machine
A-5INSTALLATION BIG RED™ 600A-5MUFFLER OUTLET PIPERemove the plastic plug covering the muffler outlettube. Using the clamp provided secure the outle
A-6INSTALLATION BIG RED™ 600A-6AUXILIARY POWER RECEPTACLESThe auxiliary power of the BIG RED™ 600 consists ofSingle Phase 60Hz Power. Output Voltage
A-7INSTALLATION BIG RED™ 600A-7CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERSShut off Welder before making any electrical con-nections.---------------
B-1OPERATIONB-1GENERAL DESCRIPTIONThe BIG RED™ 600 is a diesel engine driven welder,offering reliable DC arc welding performance, withoutstanding arc
B-2OPERATIONB-2WELDING CONTROLS (Items 1-5)1. OUTPUT RANGE SELECTOR SWITCHA 5 position switch that provides 5 overlapping out-put current settings:•
B-3OPERATIONB-35. LOCAL / REMOTE CONTROL SWITCH andREMOTE RECEPTACLEThe toggle switch provides the option of controllingthe welding output at the cont
B-4OPERATIONB-417. 120 VAC DUPLEX RECEPTACLE120VAC (5-20R) NEMA Duplex Receptacle.Receptacle is GFCI protected.18. CIRCUIT BREAKERSSingle pole 15A rat
FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.
B-5OPERATIONB-5WELDER OPERATIONDUTY CYCLEDuty Cycle is the percentage of time the load isbeing applied in a 10 minute period. For example a60% duty cy
B-6OPERATIONB-6TIGThe BIG RED™ 600 can be used for Scratch-Startof DC TIG welding applications.Use the “Output Range Selector” and “OutputControl Adju
B-7OPERATIONB-7CONSTANT CURRENT OPERATION WITHA LINCOLN ELECTRIC WIRE FEEDERLincoln Electric does NOT recommend constantcurrent semiautomatic welding
B-8OPERATIONB-8BIG RED™ 600AUXILIARY POWER:The auxiliary power is independent of the weldingpower and thus not effected by the weld control set-tings.
C-1ACCESSORIESC-1BIG RED™ 600OPTIONAL FEATURESK2641-2 FOUR WHEELED STEERABLE YARDTRAILERFor in plant and yard towing. Comes standard with aDuo-Hitch™,
D-1MAINTENANCED-1BIG RED™ 600SAFETY PRECAUTIONSHave qualified personnel do the maintenancework. Turn the engine off before working insidethe machine.
D-2MAINTENANCED-23. Remove loose dirt from element with compressedair or water hose directed from inside out.Compressed Air: 100 psi maximum with nozz
D-3MAINTENANCED-3FUEL FILTERSWhen working on the fuel system• Keep naked lights away, do notsmoke !• Do not spill fuel !------------------------------
D-4MAINTENANCED-45. Slide the quick change ring up over the elementand rotate counter clockwise until an audible clickor pop is heard. If you do not
D-5MAINTENANCED-5PREVENTING BATTERY BUCKLINGTighten nuts on battery clamp until snug.CHARGING THE BATTERYWhen you charge, jump, replace, or otherwise
ARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when welding or obs
D-6MAINTENANCED-6WELDER / GENERATOR MAINTENANCESTORAGEStore the BIG RED™ 600in clean, dry protected areas.CLEANINGBlow out the generator and controls
E-1TROUBLESHOOTINGE-1BIG RED™ 600If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contac
E-2TROUBLESHOOTINGE-2BIG RED™ 600Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedu
E-3TROUBLESHOOTINGE-3BIG RED™ 600Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedu
F-1DIAGRAMSF-1BIG RED™ 600AM22253ELECTRICSHOCKCAN KILLWARNINGDo not operate with covers removedDisconnect input power before servicingDo not touch ele
F-2DIAGRAMSF-2BIG RED™ 600M22253A4. LOCATE LEADS 3D & 6J. (SEE FIGURE 2). CUT BOTH LEADS AS SHOWN. 5. STRIP ALL FOUR LEADS 13MM (.50 in
F-3DIAGRAMSF-3BIG RED™ 600NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific d
F-4DIAGRAMSF-4BIG RED™ 600NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific d
F-5DIAGRAMSF-5BIG RED™ 600M222 23A65.101653.727.00685.810.01254.36.29159.81.2832.523.32592.231.70805.245.151146.759.501511.3N.A. CENTER OF GRAVITY WI
WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC
FOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b. Install equ
WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE
CUSTOMER ASSISTANCE POLICYThe business of The Lincoln Electric Company is manufacturing andselling high quality welding equipment, consumables, and cu
ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parra
vvThank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••• as much
viviTABLE OF CONTENTSPageInstallation...
PageMaintenance .......Section DSafety Precautions ...
A-1INSTALLATION BIG RED™ 600A-1TECHNICAL SPECIFICATIONS - BIG RED™ 600 (K2811-1)Make/Model Description Speed (RPM) Displacement Starting Capacities