Lincoln Electric V350-PRO User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
B-1
OPERATION
V350-PRO
B-1
SAFETY PRECAUTIONS
ELECTRIC SHOCK can kill.
Do not touch electrically live parts or
electrode with skin or wet clothing.
Insulate yourself from work and
ground.
Always wear dry insulating gloves.
------------------------------------------------------------------------
FUMES AND GASES can be danger-
ous.
Keep your head out of fumes.
Use ventilation or exhaust to remove
fumes from breathing zone.
------------------------------------------------------------------------
WELDING SPARKS can cause fire or
explosion.
Keep flammable material away.
Do not weld on closed containers.
------------------------------------------------------------------------
ARC RAYS can burn eyes and skin.
Wear eye, ear and body
protection.
------------------------------------------------------------
See additional warning information at
front of this operators manual.
-----------------------------------------------------------
WARNING
GENERAL DESCRIPTION
The Invertec V350-Pro offers multi-process CV, CC,
and DC welding and is rated 350 amps, 34 volts at a
60% duty cycle. The V350-Pro is available in several
versions of wire feeder connections. In the different
configurations, the V350-Pro is available in either a
Construction version (no wire feeder connection and
auxiliary power) and a Factory & Advance Process
versions (includes wire feeder connection and related
power).
DUTY CYCLE
The V350-Pro is rated at 350 amps, 60% duty cycle
(based on a 10 minute cycle). It is also rated at 275
amps, 100% duty cycle.
OPERATIONAL FEATURES and CONTROLS:
UPPER CONTROL PANEL
1. AMPS Meter
Prior to STICK or TIG operation (current flow), the
meter displays preset current value (either 2 amps
or +/- 3% (e.g. 3 amps on 100), whichever is
greater).
Prior to CV operation, the meter displays four dash-
es indicating non-presettable AMPS.
During welding, this meter displays actual average
amps.
After welding, the meter holds the actual current
value for 5 seconds. Output adjustment while in the
"hold" period results in the "prior to operation" char-
acteristics stated above. The displays blink indicat-
ing that the machine is in the "Hold" period.
2. VOLT METER
Prior to CV operation (current flow), the meter dis-
plays desired preset voltage value (+/- .5V).
Prior to STICK or TIG operation, the meter displays
the Open Circuit Voltage of the Power Source or
four dashes if the output has not been turned on.
During welding, this meter displays actual average
volts.
After welding, the meter holds the actual voltage
value for 5 seconds. The displays blink indicating
that the machine is in the "Hold" period.
Output adjustment while in the "hold" period results
in the "prior to operation" characteristics stated
above.
3. OUTPUT CONTROL
Output control is conducted via a single turn poten-
tiometer.
Adjustment is indicated by the meters as stated
above.
When in TIG modes, this control sets the maximum
welding current. Full depression of a foot or hand
Amptrol results in the preset level of current.
4. WELD TERMINALS-REMOTE / ON
Two status lights indicate the location of trigger con-
trol as determined by the "WELD TERMINALS"
push button.
If trigger control is local "weld terminals on", the ON
display will be lit.
If trigger control is remote "weld terminals remotely
controlled", the REMOTE display will be lit.
The unit will power up in "pre-determined preferred"
trigger modes.
For the Construction version all modes ON.
For the Factory and Advanced Process version
STICK = ON
TIG and CV = ON or REMOTE depending if remote
output controls are connected to the machine.
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 39 40

Comments to this Manuals

No comments