OPERATION
B-5
AUXILIARY POWER
115VAC, 42VAC and 24VAC power is available
from the two 14-pin amphenols on the rear of the
unit. (K1728-2 Construction model of the Invertec
V350-PRO (CE) does not have the amphenols)
These supplies are intended to supply power for
auxiliary equipment like wire feeders and the TIG
Module.
115VAC supply is rated at 2 amps and is protected
by a 2.5 amp breaker located by the amphenol.
42 VAC supply is rated at 5.5 amps and is protected
by a 6 amp breaker located by the amphenol.
24 VAC supply is rated at 5.5 amps and is protected
by a 6 amp breaker located by the amphenol.
LIMITATIONS
The V350-PRO (CE) is not recommended for
processes other than those listed.
The V350-PRO (CE) can only be used with the rec-
ommended equipment and options.
RECOMMENDED PROCESSES
Properly equipped, the Invertec V350-PRO (CE)
supports GMAW, FCAW, SMAW, GTAW and CAC-
A processes for a variety of materials, including
mild steel, stainless steel, cored wires, and alu-
minum
V350-PRO (CE)