MAGNUM & MAGNUM PRO CURVE 300
and 400 GMA GUN & CABLE ASSEMBLIES
MAGNUM
MAGNUM PRO CURVE
OPERATORʼSMANUAL
IM381-G
February 2013
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However,
your overall safety can be
increased by proper installation
... and thoughtful operation on
your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS
EQUIPMENT WITHOUT READ-
ING THIS MANUAL AND THE
SAFETY PRECAUTIONS CON-
TAINED THROUGHOUT. And,
most importantly, think before you
act and be careful.
Models
K574 is now located in IM646
K470-[ ] K1802-1
K471-[ ] K2286-1
K541-[ ] K2951-[ ]
K2952-[ ]
K3055-[ ]
®
®
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEBSITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Copyright © Lincoln Global Inc.
RETURN TO MAIN MENU
Page view 0
1 2 3 4 5 6 ... 30 31

Summary of Contents

Page 1 - OPERATORʼS MANUAL

MAGNUM & MAGNUM PRO CURVE 300 and 400 GMA GUN & CABLE ASSEMBLIESMAGNUMMAGNUM PRO CURVE OPERATORʼS MANUALIM381-GFebruary 2013Safety D

Page 2 - MAGNETIC FIELDS

GENERAL DESCRIPTIONMAGNUM® & MAGNUM® PRO CURVE GUNS DescriptionGun Contact Tips GasProduct Cable Wire Size Standard Diffuser Gas Cable Gun TubeNum

Page 3 - FUMES AND GASES

GENERAL DESCRIPTIONMAGNUM® & MAGNUM® PRO CURVE GUNS DescriptionGun Contact Tips GasProduct Cable Wire Size Standard Diffuser Gas Cable Gun TubeNum

Page 4

A-5GENERAL DESCRIPTION MAGNUM® & MAGNUM® PRO CURVE GUNS A-5DescriptionGun Contact Tips GasProduct Cable Wire Size Standard Diffuser Gas Cable Gu

Page 5 - REDRESSEUR

INSTALLATION MAGNUM® & MAGNUM® PRO CURVE GUNS Read this entire installation section before youstart installation.SAFETY PRECAUTIONSELECTRIC SHOC

Page 6 - Thank You

INSTALLATION MAGNUM® & MAGNUM® PRO CURVE GUNS c. For L-Tec machines that require trigger lead con-nections to be made at a terminal strip locate

Page 7 - TABLE OF CONTENTS

INSTALLATION g. Tighten the set screw in the side of the gas diffuseragainst the cable liner using the Allen wrench pro-vided. (Set Screw not requir

Page 8

INSTALLATION MAGNUM® & MAGNUM® PRO CURVE GUNS CONNECTION TO FEEDERCONNECTION TO LINCOLN FEEDERSGun cable assemblies which were assembled with aK

Page 9

INSTALLATIONc. Insert the control cable plug from the feeder triggercircuit into the mating socket on the gun cable con-nector handle. For machines wi

Page 10 - GENERAL DESCRIPTION

OPERATIONELECTRODES AND EQUIPMENTThe MAGNUM® & MAGNUM® PRO CURVE 300 and400 guns and cables have been designed for use withLincoln L-50 and L

Page 11

MAINTENANCEREMOVAL, INSTALLATION AND TRIMMINGINSTRUCTIONS FOR MAGNUM® LINERSNOTE: The variation in cable lengths prevents theinterchangeability of lin

Page 12

FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

Page 13 - INSTALLATION

MAINTENANCEf. Cut off the damaged section of cable and strip offthe outer jacket as shown in Figure 2. Be careful notto cut the insulation on the cont

Page 14

MAINTENANCEh. Pull the cut-off lead terminals off the trigger assem-bly and connect the replacement control lead termi-nals.j. Position the cable boot

Page 15

MAINTENANCEf. Check that the cable boot and cable handle are onthe cable. Slip the connector nut over the copperstrands with the threaded end out. Ass

Page 16

MAINTENANCEMAGNUM® & MAGNUM® PRO CURVE GUNSTHREAD SIZES FOR MAGNUM® 300 & 400 CONSUMABLESTHREAD SIZES FOR MAGNUM® PRO CURVE 300 & 400 CONS

Page 17

TROUBLESHOOTINGMAGNUM® & MAGNUM® PRO CURVE GUNSE-1E-1If for any reason you do not understand the test procedures or are unable to perform the test

Page 18 - OPERATION

E-2TROUBLESHOOTINGE-2MAGNUM® & MAGNUM® PRO CURVE GUNSObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not und

Page 19 - MAINTENANCE

TROUBLESHOOTINGMAGNUM® & MAGNUM® PRO CURVE GUNSObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understan

Page 20

NOTES

Page 21

NOTES

Page 22

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Page 23

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld

Page 24 - TROUBLESHOOTING

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Page 25

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB 

Page 26

iiiSAFETYiiiFOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b.

Page 27

ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parra

Page 28

vvThank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product •••as much

Page 29

TABLE OF CONTENTSPageGeneral Description ... Sectio

Page 30

GENERAL DESCRIPTIONMAGNUM® & MAGNUM® PRO CURVE GUNS A-1A-1GENERAL DESCRIPTIONThe MAGNUM® & MAGNUM® PRO CURVE 300 ampand 400 amp GMA gun and ca

Page 31

GENERAL DESCRIPTIONMAGNUM® & MAGNUM® PRO CURVE GUNS A-2A-2MAGNUM® 300300 AMPS AT 60% DUTY CYCLE WITH CO2GAS200 AMPS AT 60% DUTY CYCLE WITH MIXED G